How do you clean the fill on a cooling tower?
For large cooling systems where the predominant scale deposit is calcite, the fill can be cleaned by reducing the operating pH and/or cycles of concentration until the water is undersaturated with respect to calcite at the fill conditions.
How often should you change the fill in a cooling tower?
every 10-14 years
About cooling tower fill replacement frequency It also advisable to replace your cooling tower fills every 10-14 years to maintain the original output. You may not be aware that your cooling tower fills need immediate replacement.
How do you remove sludge from a cooling tower?
Cooling tower water that’s dirty can clog fill media and foul tubes in your chiller.
- Turn off the cooling tower fans!
- Inspect Cooling Tower For Problem Areas.
- Protect Yourself With Safety Gear.
- Spray Cooling Tower For Mold.
- Vacuum Out Sludge From Basin.
- Fill Tower Water Level.
- Clean Cooling Tower Fill Media.
Which chemical is used for cleaning cooling tower?
Chlorine dioxide – This chemical can be used as a disinfectant to destroy microorganisms and prevent recurring growth.
How often should a cooling tower be cleaned?
twice a year
While some cooling towers require more frequent cleaning due to continual operation throughout the year, OSHA (the Occupational Safety and Health Administration) recommends cooling towers be thoroughly cleaned and disinfected at least twice a year.
How do you remove scaling from a cooling tower?
Hydrochloric Acid.
Also known as aqueous hydrogen chloride or muriatic acid, hydrochloric acid is a traditional, effective approach for cleaning scale from water-cooled condensers and cooling towers. When water is heated or evaporated, scale often is left behind.
How will damaged fill affect the operation of a cooling tower?
Uneven Distribution of Water
When the water isn’t being distributed properly because the fill is damaged or clogged it dramatically impacts the performance of the cooling tower. Much more energy will need to be used to get the necessary cooling needed for your industrial application or HVAC system.
What is cooling tower fill material?
What is a Cooling tower fill material? Fill, or wet deck or surface, is a medium used in cooling towers to increase the surface area of the tower. This enlarged surface area allows for utmost contact between the air and the water flow, which as a result allowing greater evaporation rates.
Why is sulfuric acid used in cooling towers?
Sulfuric acid has been used to reduce alkalinity in cooling towers for decades. By neutralizing carbonate alkalinity with acid, scaling potential is reduced on heat exchangers, and often systems can be run with less water. However, handling large quantities of acid can be hazardous and requires special permitting.
How do you maintain pH in a cooling tower?
What You Can Do to Balance Tower Water pH
- Determine Water Quality. Start by measuring the water’s pH, alkalinity, hardness and conductivity.
- Establish Target Cycles of Concentration.
- Monitor COC and Water Performance.
- Automate Your Processes.
- Protect Your Equipment.
- Work With Your Vendor.
How much does it cost to clean a cooling tower?
Costs for Cooling Tower Cleaning and Disinfection
Typically cooling tower cleaning packages will cost you somewhere between $5,000 – $15,000. Costs can fluctuate based on: Amount of remediation necessary. Size and complexity of systems.
What is cooling tower fill?
Fill, or wet deck or surface, is a medium used in cooling towers to increase the surface area of the tower. Increased surface area allows for maximum contact between the air and the water, which allows for greater evaporation rates.
What causes calcium deposits on cooling tower?
Scale deposits typically occur when the concentrations of dissolved salts in the cooling water exceed their solubility limits and accumulate on surfaces that are in contact with the water.
What is the purpose of the fill in a cooling tower?
The principle of operation of cooling tower fill is to put as much water surface area in contact with as much air as possible, for the longest amount of time possible. Film fills allow the water to form thin flowing sheets to expose as much water surface area as possible to the interacting flow.
Why is fill important on a cooling tower?
Which filling material is more energy efficient for cooling tower?
In case of cooling towers, which type of fill media are more ‘energy efficient’? Fills made of PVC, polypropylene, and other polymers are more energy efficient. Wet Bulb Temperature is an important factor in performance of evaporative water cooling equipment.
Why sodium hypochlorite is used in cooling tower?
For most cooling water systems, a 12.5 percent sodium hypochlorite solution is used for chlorination because it is safe to use and relatively more economical than chlorine gas or other solid chlorine sources.
What causes high pH in cooling tower?
The circulating water is aerated each time it passes over the cooling tower. This reduces the carbon dioxide concentration in the water to the equilibrium value for the atmospheric conditions, causing the pH to rise. The rapid increase in pH across the tower can lead to calcium carbonate scaling on the tower fill.
What is the life expectancy of a cooling tower?
Cooling Tower Replacement can be a costly proposition and the average life expectancy of a commercial cooling tower, according to most manufacturers, is 15 – 20 years*, before they need to be rebuilt or replaced.
Which fill is best for cooling tower?
Splash fill media were traditionally made from wood, but modern cooling tower fill material is made from PVC. PVC is more efficient as it facilitates better heat transfer.
How can the hardness of a cooling tower be reduced?
In general, the calcium hardness in the cooling tower should be maintained within the range of 350 to 400 ppm on a non-acid treatment program.
…
Hardness reduction or removal can be accomplished by:
- Lime softening,
- Sodium ion exchange (water softener), or.
- Reverse osmosis.
Why are biocides added to cooling tower water?
Why Do I Need Biocide In My Cooling Tower? Cooling water provides an ideal environment for biological growth, including Legionella. Because Legionella bacteria can be a health hazard, treating your cooling water properly with the most effective biocide (bacterial disinfectant) is an extremely important task.
What material is cooling tower fill made of?
rigid PVC
Today, the most commonly used film fill sheet material is rigid PVC (Cooling Technology Institute Std. 136). It is durable, provides a long service life, is excellent for wetting (conditioned to allow surfaces to be covered completely by water), is self-extinguishing and can be formed into many shapes (figure 1).
What is the fill in a cooling tower?
Which types of fills generally used in cooling towers?
There are two basic types of fill: splash fill and film fill. Splash fill is designed to interrupt the water and cause, as the name suggests, splashing. Film fill, on the other hand, is made up of sheets of material that the water travels across.