What is VSS in Cisco switch?

What is VSS in Cisco switch?

The Cisco Catalyst 6500 Series Virtual Switching System (VSS) allows the clustering of two or more physical chassis together into a single, logical entity. This technology allows for enhancements in all areas of network design, including high availability, scalability, management, and maintenance.

How do I check my Cisco VSS status?

1) To displays the virtual switch domain number, and the switch number and role for each of the switches you can use “show switch virtual” command. 3) To displays the role, switch number, and priority for each of the switch in the VSS use “show switch virtual role” command.

How can you tell if a switch is active in VSS?

Configure Virtual Switch Domain

The next step is to assign a priority to determine what switch will become active or standby. The higher the priority the more likely you will become the active switch. Switch 1 will have a priority of 110 and switch 2 a priority of 100. This means SW1-VSS will become the active switch.

What is VSL Cisco?

VSL is used to carry on proprietary encapsulated frames also control plane messages to form a single device, one supervisor the active one controls both chassis with second supervisor acting as hot standby as in a single chassis with two supervisors.

What is a VSS pair?

VSS stands for Virtual Switching System. It is used to create one logical switch by combining two physical switches. It is a Cisco proprietary. This feature is supported on Catalyst 4500 & 6500 modular switches.

How many switchs are there in VSS?

A Virtual Switching System (VSS) is a Cisco proprietary technology that interconnects two physical switches and logically makes them one switch with interconnected control and management planes.

Is VSS active active?

In Virtual Switch Mode, while only one Control plane is active, both Data Planes (Switch Fabric’s) are active, and as such, each can actively participate in the forwarding of data …

How do I set up VSS?

A.

  1. Open Windows Explorer or the Microsoft Management Console (MMC) Disk Management snap-in, then right-click the drive.
  2. Select Properties from the context menu.
  3. Select the Shadow Copies tab.
  4. Under “Select a volume,” select the volume for which you want to enable Shadow Copies.
  5. Click Settings to configure VSS.

What is VSL in VSS?

Virtual Switch Link Initialization:
The VSS initialization process must determine which chassis switch will become active for the VSS. In order to determine the chassis active & standby roles, the Virtual Switch Link (VSL) must be initialized and UP for control plane communication.

What is vPC and VSS?

vPC:- Control messages are carried by CFS over Peer Link and a Peer keepalive link is used to check heartbeats and detect dual-active condition; VSS:- Control messages and Data frames flow between active and standby via VSL; 10 Helpful.

What is SSO in VSS?

In VSS mode, supervisor engine redundancy operates between the active and standby chassis, using stateful switchover (SSO) and nonstop forwarding (NSF). The peer chassis exchange configuration and state information across the VSL and the standby supervisor engine runs in hot standby mode.

What is the difference between VSS and stacking?

Stackwise Virtual and VSS are technically the same. They are called what they are because of marketing. In both instances, two physical chassis for a single logical unit which makes management easier and enables cross-chassis Etherchannel.

What is difference between stacking and VSS?

A VSS will allow two physical Cisco Catalyst Series Switches to operate as a single logical virtual switch called a virtual switching system.

Comparison Table: Stacking vs VSS.

FEATURE STACKING VSS
Distance Supported Limited by distance VSS members can be in geographically distant locations

What is difference between VSS and vPC?

Correct, VSS is only for Catalyst series switches and vPC is for the Nexus switches which are mainly designed to be used in data centers. As for as connecting the Cisco to Dell and other vendors, you can use LACP for bundling multiple uplinks in one logical connection.

Should VSS be set to automatic?

The Volume Shadow Copy service doesn’t need to be running all the time or set to Automatic. It’s only used when an app requests it, e.g. a backup app. There is no reason to have it set to anything but Manual.

How do I set limits on VSS?

Creating a new VSS threshold
The Settings page, for the selected drive, opens. In the Storage area section, ensure that the Maximum size radio button is set to Use limit, then use the up/down arrows in the adjacent box to set the limit to between 15% and 20% of the total drive capacity.

What is VSS in Nexus switch?

VSS (Virtual Switching System)
VSS mode, a Catalyst 6500 feature, allows a pair of Catalyst 6500s to be joined together into one logical switch with a unified control plane. This allows for multi-chassis link aggregation and subsequently high availability, without Spanning Tree concerns.

What is difference between vPC and VSS?

2) In VSS there will be single control plane for both the switches, where as in vPC there will be separate control plane for every switch. 3) VSS can support L3 port-channels across multiple chassis,however, vpc is used for L2 port-channels only.

How many control planes are there in VSS?

Plane 1 Control Plane
Comparison Table: Stacking vs VSS

FEATURE STACKING VSS
Chassis members Scalable upto 8-9 members 2 members at max
Platform switches 2960 , 3750 , 3650 , 3850 6500 , 6800 , 4500
Control Plane 1 Control Plane 1 Control Plane
Switch Size On smaller / Access layer switches On Core or Aggregation layer switches

What is the difference between VSS and HSRP?

VSS is virtualization technology, 2 devices are seen like only 1. So Spanning tree is not required. About HSRP is used to create high availability between 2 networks creating a virtual IP, this virtual IP will represent the gateway for the network.

What is Cisco VSS and vPC?

VSS is the 6500 technology to logically combine two physically separate chassis. As you point out vPC is a Nexus technology, the Catalyst equivalent is MEC (Multi-chassis Ether Channel). From your message you are correct in thinking that using etherchannel from the TOR switches to the core is the correct solution.

How do I know if shadow copies are enabled?

Open Windows Explorer or the Microsoft Management Console (MMC) Disk Management snap-in, then right-click the drive. Select Properties from the context menu. Select the Shadow Copies tab. Under “Select a volume,” select the volume for which you want to enable Shadow Copies.

How do I check my VSS storage?

Shadow Copy space usage

  1. Click start, un the run/search box type CMD then right click the CMD. EXE icon on the search menu and select Run as Administrator.
  2. Type the following command: vssadmin list shadowstorage then press the Enter Key.

How do I increase shadow copy limit?

Select Configure Shadow Copies… from the right-click menu. This should bring up the Shadow Copies window. In the Shadow Copies window, notice how, if the Used field is blank, there is no storage space currently allocated. Click on the volume for which you want to allocate shadow copy storage and hit Settings.

What is a VSS cluster?

The Cisco Catalyst 6500 Series Virtual Switching System (VSS) allows the clustering of two chassis together into a single, logical entity. This technology allows for enhancements in all areas of network design, including high availability, scalability, management, and maintenance.

Related Post