RG-58 (50 ohm) is about 0.195″, quite lossy, suitable only for mobile installations (typically < 20 feet, < 150 watts). RG-6 (75 ohms) is about 0.332″, typically used for cable/satellite TV. RG-8X (50 ohm); and and RG-59 (75 ohm) are about 0.24 inch.

What is acceptable cable loss?

If the return loss is 10 dB, 10% of the power is returned. While different systems have different acceptable return loss limits, 15 dB or better is a common system limit for a cable and antenna system.

How do you calculate cable loss?

Thus, the cable power loss Ploss in kilowatts is equal to 1000 times the square of the current(ampere), the resistivity(Ohm-meter), the number of the cores divided by the cross-section area (square mm) of the conductor.

Is RG58 low loss?

Features and benefits: Extremely Low Loss RG58 coaxial cable, at a low price. Halogen free and flame retardant cable types available on request. Excellent return loss performance and attenuation.

How far can you run RG58 cable?

RG-58 in versions RG-58A/U or RG-58C/U was once widely used in “thin” Ethernet (10BASE2), for which it provides a maximum segment length of 185 meters.

Is LMR 400 the same as RG58?

Conclusion of LMR400 and RG58’s differences

Although LMR400 cable has low loss, it is thicker and less flexible than RG58 or LMR240 cable, making it more difficult to work with. It comes in lengths ranging from 2′ to 100′ and is designed to be used with antennas and amplifiers that don’t come with cabling.

How much DBI do you lose per foot of cable?

What is the Cable Loss for Mobile Mark Antenna’s Cables?

Loss per Foot
Common Cable Type 900 MHz 2,000 MHz
RG-174 0.32 dB 0.49 dB
RG-58 0.14 dB 0.21 dB
RF-195 0.10 dB 0.15 dB

Why return loss should be less than 10 dB?

The return loss measures the reflected wave to the incident wave, that is RL = -20 log(Γ). So, a return loss of -10 dB means that the reflected wave is 10 dB lower than the incident wave. This is approximately equal to a reflection coefficient of 0.3, so 30% of the incident wave is wasted.

What is dB loss in cable?

Expressed in decibels (dB), loss of signal happens along the length of any cable. It is a natural phenomenon that occurs for any type of transmission—electrical or data. And the longer the cable, the greater the loss. Loss also occurs at any connection points along the way such as connectors or splices.

What is RF cable loss?

RF coaxial cable loss formula
The cable Loss consists of conductor wire loss, insulation loss and connector loss. As mentioned in the equation, conductor loss (K1) relates to square root of frequency, insulation loss (K2) relates to frequency and connector loss relates to connectors used in the cable.

What is the difference between RG58 and rg59?

Q: What is the difference between RG-58 and RG-59 coaxial cable? A: RG-58 is 50-ohm coaxial cable and is typically used for radio communications and thin Ethernet networks. RG-59 is 75-ohm coaxial cable for CCTV and cable TV. Some also use RG-6 for video connections.

How many watts can RG-58 handle?

The outside diameter of RG-58 is around 0.2 inches (5 mm). RG-58 weighs around 0.025 lb/ft (37 g/m), exhibits approximately 25 pF/ft (82 pF/m) capacitance and can tolerate a maximum of 300 V potential (1800 W).

Can I use 75 ohm cable instead 50?

Sure, you can use 75 ohm coax instead of 50 ohm. In some cases (such as feeding a dipole), 75 ohm coax may be a better match to the load than 50 ohm. In other cases (such as feeding a vertical), it may be a worse match. You may not even need to do additional matching.

What is better than RG58?

RG8. RG8 is a thicker 50 ohm cable, at 12 AWG, that can provide a stronger signal than RG58. It is mainly used for amateur radio.

What does LMR mean in cable?

Low-Loss Coaxial Cables
The LMR® Low-Loss Coaxial Cables are part of Allied Wire and Cable’s extensive stock of Coaxial Cable. This collection of Low-Loss Coax has a variety of cables that are suitable for indoor, outdoor, Riser, Plenum, and video applications.

What coaxial cable has the least amount of signal loss?

Series 11 is the largest, has the least amount of signal loss over length, but is bulky, hard to install, and relatively expensive when compared to Series 6 coaxial cables. Series 6 is the most commonly used size due to the excellent trade off in price, size, handling and signal loss.

How long can you run coax cable without loss?

The longer the coax run, the more loss and the more expensive it gets. The signal arriving at the receiver from anything longer than 100 feet of RG8X is probably going to cause trouble. Runs over 200 feet without amplification are only a dim possibility.

Is higher return loss better?

Return loss is a measurement parameter that expresses how well a device or line matches. A high return loss is advantageous as it will result in a lower insertion loss.

What is acceptable VSWR?

A VSWR of less than 1.5:1 is ideal, a VSWR of 2:1 is considered to be marginally acceptable in low power applications where power loss is more critical, although a VSWR as high as 6:1 may still be usable with the right equipment.

How much is a loss of 3db?

A 3 dB loss means half the power. For example, a system with 40 watts of input power and a 6 dB insertion loss will only have 10 watts of output power. dB: Decibel, a logarithm (equal to 10 times) ratio of the difference between two values.

What is the maximum dB loss for fiber?

TIA specifies a maximum value for fiber connectors of 0.75dB because it is considered worst-case scenario. It is therefore rather high and not exactly realistic since most fiber connectors typically have a range of 0.3 to 0.5dB for standard loss and 0.15 to 0.2 for low loss.

How is RF cable loss calculated?

You can measure cable loss by placing the short end of the cable in the meter; once the signal reflects back, you can calculate the power loss of the cable. Most cable and antenna analyzers have a cable loss mode that displays the average cable loss of a particular frequency range.

Why is Series 59 coaxial cable no longer used?

RG 59 has a smaller conductor than RG 6, which means that it can’t achieve the same signal quality as RG 6. The way its shielding is designed also means that it doesn’t keep Gigahertz level signals inside the conductor very well. This is why RG 59 probably isn’t a good choice for your TV or internet connection.

How far can you run RG 58 cable?

Which is better 50 ohm or 75 ohm?

Interestingly, the smaller the Ohm number, the better the booster performs, so systems with 50 Ohm are stronger than those with 75 Ohm. While 50 Ohm is stronger, it isn’t necessary for most homes or small buildings and covers anywhere from 7,500 to 100,000 sq ft. Likewise, these cables run around 100 ft. long.