Can you use 10mm as main earth?
I confess I have used 10mm main earth conductor when the main cutout is 60A, usually when the 6mm bare ‘earth tail’. is sweated onto the main cable.
…
See Also:
Technical discussion forums | |
---|---|
· | Wiring and the regulations |
· | Other and general engineering discussions |
Archived categories |
What is 10 mm wire used for?
Application: 10mm Electrical Cables are suitable for laying at the fixed places. It is widely used in connecting of power device, lighting, daily electrical appliance, instrument etc. with AC rated voltage up to and including 600/1000V(U0/U).
What is 10mm twin and earth used for?
10mm twin and earth cable is often used for shower installations and cooking circuits. It is important that a suitably qualified professional assesses the requirements of the work as choosing the incorrect and wrong size of cable could lead to distressing consequences.
How big is the earth in a 10mm cable?
6.0mm
what size earth in 10mm cable? The outer diameter for earth wire 10mm is 6.0mm.
What size should earth cable be?
Earth Bonding Cable Size Selection
Line Conductor or Neutral Conductor of PME supplied | mm2 | 50 |
---|---|---|
Earthing Conductor not buried or buried and protected against corrosion and mechanical damage | mm2 | 25 |
Main Protective Bonding Conductor | mm2 | 16 |
Main Protective Bonding Conductor for PME supplies (TN-C-S) | mm2 | 16 |
What size should earth bonding be?
Main Bonding (Earthing)
Main Bonding is the use of a separate thick (10mm) green and yellow copper cable, to connect the Water, Gas and Oil services to the Earth Terminal in or adjacent to your consumer unit.
How many amps can a 10mm twin and earth take?
Twin And Earth & Flat Cable Technical Specifications
NOMINAL CROSS SECTIONAL AREA mm2 | REFERENCE METHOD A* (IN CONDUIT IN WALL) Amps | REFERENCE METHOD C* (CLIPPED DIRECT) Amps |
---|---|---|
4mm | 26 Amps | 37 Amps |
6mm | 32 Amps | 47 Amps |
10mm | 44 Amps | 64 Amps |
16mm | 57 Amps | 85 Amps |
How many amps can a 10mm?
Cable Size Ratings Tables in Amps
Cable size | Rating in Amps |
---|---|
2.5mm | 27 |
4mm | 37 |
6mm | 47 |
10mm | 65 |
Is 10mm cable OK for 10.5 kW shower?
The higher the kW rating of a shower, the greater the flow of heated water from the showerhead will be; so making sure to get the right size cable for your electric shower is vital.
Cable Sizes by kW Rating.
kW Electric Shower Rating | Recommended Cable Size |
---|---|
10,000 (10 kW) | 10mm2 |
10,500 (10.5 kW) | 16mm2 |
11,000 (11 kW) | 16mm2 |
How many amps can a 10mm twin and earth cable take?
10mm Twin And Earth Current Carrying Capacity
NOMINAL CROSS SECTIONAL AREA mm2 | REFERENCE METHOD A* (IN CONDUIT IN WALL) Amps | REFERENCE METHOD C* (CLIPPED DIRECT) Amps |
---|---|---|
10mm | 44 Amps | 64 Amps |
What size is earth in 10mm twin and earth?
Twin and Earth (T+E)
CSA | Overall Dimensions | Diameter of each Live/ |
---|---|---|
Neutral copper core strand | ||
6mm² | 13.5mm x 7mm | 1.04mm |
10mm² | 17.1mm x 10mm | 1.35mm |
16mm² | 19.4mm x 10mm | 1.71mm |
How thick should the earthing wire be?
1.5 mm is fine. You don’t need to use both of the earth terminals in a normal domestic environment though, it’s only used in situations where ‘high integrity’ earthing is needed, usually where there are lots of computers on the circuit.
What is 16mm earth cable used for?
The table below shows the current carrying capacity of 16mm twin and earth cable. This cable is mainly used for large electric domestic or commercial cooker and shower circuits rated at 50A AMP.
How do I choose earthing cable size?
Earthing conductor size calculation Formula:
- Earth conductor size PE(Sqmm) =1.5 x √ (I(Fault-A)2 x t(s)) / k.
- Earth Conductor size = √ (200002 x 0.5) / 80.
- However, the size of the conductor is above the resultant size.
What are the different size of earthing?
GI Earthing Wire, Gauge Size: 8, Thickness: 5-10 Mm
Thickness | 5-10 mm |
---|---|
Gauge Size | 8 |
Usage/Application | Industrial |
Surface Finish | Powder Coated |
Packaging Type | Roll |
How many kW can a 10mm cable take?
Cable Sizes by kW Rating
kW Electric Shower Rating | Recommended Cable Size |
---|---|
9000 (9 kW) | 10mm2 |
9500 (9.5 kW) | 10mm2 |
10,000 (10 kW) | 10mm2 |
10,500 (10.5 kW) | 16mm2 |
What is maximum current for 10mm cable?
44 Amps 64 Amps
Twin And Earth & Flat Cable Technical Specifications
NOMINAL CROSS SECTIONAL AREA mm2 | REFERENCE METHOD A* (IN CONDUIT IN WALL) Amps | REFERENCE METHOD C* (CLIPPED DIRECT) Amps |
---|---|---|
4mm | 26 Amps | 37 Amps |
6mm | 32 Amps | 47 Amps |
10mm | 44 Amps | 64 Amps |
16mm | 57 Amps | 85 Amps |
What kW can a 10mm cable take?
10mm cable should be used on showers of 8.5kw and above, so yes if your fitters are saying that the best showers are those with the highest rating (e.g.10.8Kw), then they are right in that the 6mm cable is inadequate.
How many amps can 10mm cable take?
Can I run a 10kw shower on 6mm cable?
Fuses and switches should be rated at 32 amps. Showers up to 9kw may carry a 6mm cable as long as the shower unit is within 18 meters of the fuseboard. Fuses and switches should be rated at 40 amps. Showers up to 12.5kw should carry a 10mm cable to units within 35 metres of the fuseboard.
What is a 10mm cable rated at?
How many amps can 10 mm cable carry?
Why is earthing wire thin?
If the current is smaller then the resistance can be increased by using thinner wires without too much of a loss of energy.
What size cable is used for earth bonding?
Bonds should be at least half the size required for the earthing conductor, min 6mm2. So provided your earthing conductor need not be > 12mm2 I don’t see a problem. You’d probably have to use the adiabatic equation to prove that <16mm2 is OK, but chances are it would be.
How is earthing size calculated?
Required Earthing Conductor size = Cross sectional area x Total allowance x Safety factor. Required Earthing Conductor size = 1125 Sq.mm say 1200 Sq.mm. Hence, Considered 1Nox12x100 mm GI Strip or 2Nox6 x 100 mm GI Strips.